An investigation on methods for free-field comparison calibration of measurement microphones

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Standard

An investigation on methods for free-field comparison calibration of measurement microphones. / Barrera Figueroa, Salvador; Moreno Pescador, Guillermo Sergio; Jacobsen, Finn; Rasmussen, Knud; Cutanda Henriquez, Vicente; Juhl, Peter Møller.

Proceedings of Internoise 2010: 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal Duration:,15 Jun 2010 → 16 Jun 2010. Vol. 39 Portugal, Lisbon, 2010. p. 1-10.

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Harvard

Barrera Figueroa, S, Moreno Pescador, GS, Jacobsen, F, Rasmussen, K, Cutanda Henriquez, V & Juhl, PM 2010, An investigation on methods for free-field comparison calibration of measurement microphones. in Proceedings of Internoise 2010: 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal Duration:,15 Jun 2010 → 16 Jun 2010. vol. 39, Portugal, Lisbon, pp. 1-10, 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal, Lisbon, Portugal, 15/07/2010.

APA

Barrera Figueroa, S., Moreno Pescador, G. S., Jacobsen, F., Rasmussen, K., Cutanda Henriquez, V., & Juhl, P. M. (2010). An investigation on methods for free-field comparison calibration of measurement microphones. In Proceedings of Internoise 2010: 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal Duration:,15 Jun 2010 → 16 Jun 2010 (Vol. 39, pp. 1-10).

Vancouver

Barrera Figueroa S, Moreno Pescador GS, Jacobsen F, Rasmussen K, Cutanda Henriquez V, Juhl PM. An investigation on methods for free-field comparison calibration of measurement microphones. In Proceedings of Internoise 2010: 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal Duration:,15 Jun 2010 → 16 Jun 2010. Vol. 39. Portugal, Lisbon. 2010. p. 1-10

Author

Barrera Figueroa, Salvador ; Moreno Pescador, Guillermo Sergio ; Jacobsen, Finn ; Rasmussen, Knud ; Cutanda Henriquez, Vicente ; Juhl, Peter Møller. / An investigation on methods for free-field comparison calibration of measurement microphones. Proceedings of Internoise 2010: 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal Duration:,15 Jun 2010 → 16 Jun 2010. Vol. 39 Portugal, Lisbon, 2010. pp. 1-10

Bibtex

@inproceedings{32b069596d47489991a228a04722884d,
title = "An investigation on methods for free-field comparison calibration of measurement microphones",
abstract = "Free-field comparison calibration of measurement microphones requires that a calibrated reference microphone and a test microphone are exposed to the same sound pressure in a free field. The output voltages of the microphones can be measured either sequentially or simultaneously. The sequential method requires the sound field to have good temporal stability. The simultaneous method requires instead that the sound pressure is the same in the positions where the microphones are placed. In this paper the results of the application of the two methods are compared. A third combined method is suggested.",
author = "{Barrera Figueroa}, Salvador and {Moreno Pescador}, {Guillermo Sergio} and Finn Jacobsen and Knud Rasmussen and {Cutanda Henriquez}, Vicente and Juhl, {Peter M{\o}ller}",
year = "2010",
language = "English",
volume = "39",
pages = "1--10",
booktitle = "Proceedings of Internoise 2010",
note = "39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal ; Conference date: 15-07-2010 Through 16-07-2010",

}

RIS

TY - GEN

T1 - An investigation on methods for free-field comparison calibration of measurement microphones

AU - Barrera Figueroa, Salvador

AU - Moreno Pescador, Guillermo Sergio

AU - Jacobsen, Finn

AU - Rasmussen, Knud

AU - Cutanda Henriquez, Vicente

AU - Juhl, Peter Møller

PY - 2010

Y1 - 2010

N2 - Free-field comparison calibration of measurement microphones requires that a calibrated reference microphone and a test microphone are exposed to the same sound pressure in a free field. The output voltages of the microphones can be measured either sequentially or simultaneously. The sequential method requires the sound field to have good temporal stability. The simultaneous method requires instead that the sound pressure is the same in the positions where the microphones are placed. In this paper the results of the application of the two methods are compared. A third combined method is suggested.

AB - Free-field comparison calibration of measurement microphones requires that a calibrated reference microphone and a test microphone are exposed to the same sound pressure in a free field. The output voltages of the microphones can be measured either sequentially or simultaneously. The sequential method requires the sound field to have good temporal stability. The simultaneous method requires instead that the sound pressure is the same in the positions where the microphones are placed. In this paper the results of the application of the two methods are compared. A third combined method is suggested.

M3 - Article in proceedings

VL - 39

SP - 1

EP - 10

BT - Proceedings of Internoise 2010

CY - Portugal, Lisbon

T2 - 39th International Congress and Exposition on Noise Control Engineering - Lisbon, Portugal

Y2 - 15 July 2010 through 16 July 2010

ER -

ID: 226076680