Tailoring the energy resolution of MIRACLES, the time-of-flight – backscattering spectrometer at the ESS: An updated proposal for the chopper cascade
Publikation: Bidrag til tidsskrift › Konferenceartikel › Forskning › fagfællebedømt
A cost-effective chopper layout for the chopper cascade of MIRACLES, the time-of-flight backscattering spectrometer of the European Spallation Source is described. The main driving force is the capability to display a versatile and flexible selection of configuration modes, taking advantage of the long ESS pulse and tailoring the instrument resolution ad hoc, and covering a broad range of observation times from 10 ps to the ns. A key element for the design here presented is the feasibility to reach an energy resolution contribution from the incident neutron beam of ∼1.2 μeV, while keeping the same performance of MIRACLES conceptual design. The present optimized concept results in a well-balanced combination with the contribution from the secondary spectrometer time-of-flight energy resolution, yielding a total energy resolution of 2 μeV at best, and 2.5 μeV when the primary and secondary spectrometer contributions are matched.
Originalsprog | Engelsk |
---|---|
Tidsskrift | Physica B: Condensed Matter |
Vol/bind | 564 |
Sider (fra-til) | 64-68 |
Antal sider | 5 |
ISSN | 0921-4526 |
DOI | |
Status | Udgivet - 3 apr. 2019 |
ID: 217477930