Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Standard

Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2. / Bertelsen, H.; Montoya, G. Carrillo; Deviveiros, P. O.; Eifert, T.; Galster, G.; Glatzer, J.; Haas, S.; Marzin, A.; Oliveira, M. V. Silva; Pauly, T.; Schmieden, K.; Spiwoks, R.; Stelzer, J.

I: Journal of Instrumentation, Bind 11, Nr. 2, C02020, 08.02.2016.

Publikation: Bidrag til tidsskriftTidsskriftartikelfagfællebedømt

Harvard

Bertelsen, H, Montoya, GC, Deviveiros, PO, Eifert, T, Galster, G, Glatzer, J, Haas, S, Marzin, A, Oliveira, MVS, Pauly, T, Schmieden, K, Spiwoks, R & Stelzer, J 2016, 'Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2', Journal of Instrumentation, bind 11, nr. 2, C02020. https://doi.org/10.1088/1748-0221/11/02/C02020

APA

Bertelsen, H., Montoya, G. C., Deviveiros, P. O., Eifert, T., Galster, G., Glatzer, J., Haas, S., Marzin, A., Oliveira, M. V. S., Pauly, T., Schmieden, K., Spiwoks, R., & Stelzer, J. (2016). Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2. Journal of Instrumentation, 11(2), [C02020]. https://doi.org/10.1088/1748-0221/11/02/C02020

Vancouver

Bertelsen H, Montoya GC, Deviveiros PO, Eifert T, Galster G, Glatzer J o.a. Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2. Journal of Instrumentation. 2016 feb. 8;11(2). C02020. https://doi.org/10.1088/1748-0221/11/02/C02020

Author

Bertelsen, H. ; Montoya, G. Carrillo ; Deviveiros, P. O. ; Eifert, T. ; Galster, G. ; Glatzer, J. ; Haas, S. ; Marzin, A. ; Oliveira, M. V. Silva ; Pauly, T. ; Schmieden, K. ; Spiwoks, R. ; Stelzer, J. / Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2. I: Journal of Instrumentation. 2016 ; Bind 11, Nr. 2.

Bibtex

@article{a976fb9105064b78bb12e21671c42732,
title = "Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2",
abstract = "The ATLAS Central Trigger Processor (CTP) is responsible for forming the Level-1 trigger decision based on the information from the calorimeter and muon trigger processors. In order to cope with the increase of luminosity and physics cross-sections in Run 2, several components of this system have been upgraded. In particular, the number of usable trigger inputs and trigger items have been increased from 160 to 512 and from 256 to 512, respectively. The upgraded CTP also provides extended monitoring capabilities and allows to operate simultaneously up to three independent combinations of sub-detectors with full trigger functionality, which is particularly useful for commissioning, calibration and test runs. The software has also undergone a major upgrade to take advantage of all these new functionalities. An overview of the commissioning and the operation of the upgraded CTP during the LHC Run 2 is given.",
keywords = "Control and monitor systems online, Trigger algorithms, Trigger concepts and systems (hardware and software)",
author = "H. Bertelsen and Montoya, {G. Carrillo} and Deviveiros, {P. O.} and T. Eifert and G. Galster and J. Glatzer and S. Haas and A. Marzin and Oliveira, {M. V. Silva} and T. Pauly and K. Schmieden and R. Spiwoks and J. Stelzer",
year = "2016",
month = feb,
day = "8",
doi = "10.1088/1748-0221/11/02/C02020",
language = "English",
volume = "11",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "Institute of Physics Publishing Ltd",
number = "2",

}

RIS

TY - JOUR

T1 - Operation of the upgraded ATLAS Central Trigger Processor during the LHC Run 2

AU - Bertelsen, H.

AU - Montoya, G. Carrillo

AU - Deviveiros, P. O.

AU - Eifert, T.

AU - Galster, G.

AU - Glatzer, J.

AU - Haas, S.

AU - Marzin, A.

AU - Oliveira, M. V. Silva

AU - Pauly, T.

AU - Schmieden, K.

AU - Spiwoks, R.

AU - Stelzer, J.

PY - 2016/2/8

Y1 - 2016/2/8

N2 - The ATLAS Central Trigger Processor (CTP) is responsible for forming the Level-1 trigger decision based on the information from the calorimeter and muon trigger processors. In order to cope with the increase of luminosity and physics cross-sections in Run 2, several components of this system have been upgraded. In particular, the number of usable trigger inputs and trigger items have been increased from 160 to 512 and from 256 to 512, respectively. The upgraded CTP also provides extended monitoring capabilities and allows to operate simultaneously up to three independent combinations of sub-detectors with full trigger functionality, which is particularly useful for commissioning, calibration and test runs. The software has also undergone a major upgrade to take advantage of all these new functionalities. An overview of the commissioning and the operation of the upgraded CTP during the LHC Run 2 is given.

AB - The ATLAS Central Trigger Processor (CTP) is responsible for forming the Level-1 trigger decision based on the information from the calorimeter and muon trigger processors. In order to cope with the increase of luminosity and physics cross-sections in Run 2, several components of this system have been upgraded. In particular, the number of usable trigger inputs and trigger items have been increased from 160 to 512 and from 256 to 512, respectively. The upgraded CTP also provides extended monitoring capabilities and allows to operate simultaneously up to three independent combinations of sub-detectors with full trigger functionality, which is particularly useful for commissioning, calibration and test runs. The software has also undergone a major upgrade to take advantage of all these new functionalities. An overview of the commissioning and the operation of the upgraded CTP during the LHC Run 2 is given.

KW - Control and monitor systems online

KW - Trigger algorithms

KW - Trigger concepts and systems (hardware and software)

U2 - 10.1088/1748-0221/11/02/C02020

DO - 10.1088/1748-0221/11/02/C02020

M3 - Journal article

AN - SCOPUS:84960155502

VL - 11

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 2

M1 - C02020

ER -

ID: 179274478